Wall Coverings · Furniture specification

Grey Microcement Finish Furniture Specifications

Grey Microcement Finish for hotel guestrooms, corridors, lobbies and feature joinery, selected as a complete installed system rather than by surface colour alone.

Current material reference

Approx. 2–3 mm layered mineral/resin system over prepared substrate

Project-specific system · final build-up must be tested

Material decision summary

Project suitability at a glance.

Treat the finish, substrate, adhesive or subframe, joints and installation method as one tested system.

Best for

  • +Seamless feature surfaces where substrate preparation and sealer can be controlled

Avoid when

  • Movement joints, waterproofing or future patch variation cannot be managed
Traffic level
High
Maintenance
Medium
Visual variation
Medium
Relative budget
●●●○
Suitable environments
Interior · High traffic · Wet area

Material overview

Most requested furniture applications

Select after confirming substrate, fire requirement, cleaning, acoustics, humidity and joint layout. A full installed mock-up is the most reliable approval reference.

Wall Coverings — Application view: completed coordinated wall system
01 Application view: completed coordinated wall system
01 Hotel guestrooms and corridors
02 Lobby, restaurant and reception walls
03 Feature joinery and acoustic zones

Material-specific authority schedule

Ten controls owned by this exact material—not inherited category rows. Final values are confirmed from supplier data, the project sample and shop drawings.

Grey Microcement Finish Current material reference
01Grey Microcement Finish
Type II Vinyl Wallcovering Current material reference
02Type II Vinyl Wallcovering
Declared project reference
Grey Microcement Finish: Approx. 2–3 mm layered mineral/resin system over prepared substrate
Exact material identity
Grey microcement layered mineral/resin system, typically about 2–3 mm only where selected manufacturer confirms; substrate and sealer included.
Technical system definition
A thin layered mineral/resin microcement finish—typically about 2–3 mm—over a prepared stable substrate, completed with compatible sealer/topcoat. It is a system, not a standalone cement colour.
Selection differentiator
Continuous hand-trowelled tonal movement across walls, joinery and selected furniture.
Critical approval decision
The substrate and waterproofing carry movement/water control. Microcement cannot bridge unresolved cracks, joints or failed wet-area waterproofing.
Non-equivalent substitute
Cement paint, polished plaster and another microcement brand are not equivalent layered systems.
Fabrication focus
Repair cracks, honour movement joints, reinforce as required and apply one manufacturer’s full cure/sealer sequence.
GCC exposure limit
Wet areas depend on underlying waterproofing; hot dry application can shorten working time and alter colour.
Material-specific care rule
Use sealer-compatible neutral cleaner and renew topcoat by condition, not a generic calendar.
Reject the delivery when
Reject substrate read-through, hairline cracking, dark water patches, trowel burns, pinholes or visible patch repair outside control.

Approval pack

Documents required before ordering.

Project-specific system · final build-up must be tested

  • Grey Microcement Finish: Identity/source evidence: Grey microcement layered mineral/resin system, typically about 2–3 mm only where selected manufacturer confirms; substrate and sealer included.
  • Grey Microcement Finish: Signed selection evidence: One manufacturer/system warranty covers all layers and substrate route.
  • Grey Microcement Finish: Second technical gate: Substrate hold point and waterproofing test are complete before finish.
  • Grey Microcement Finish: Factory close-out: Repair cracks, honour movement joints, reinforce as required and apply one manufacturer’s full cure/sealer sequence.

Lead time & availability

Confirmed after source, finish and quantity selection

Family inspection atlas

A shared visual reference for construction and fabrication.

This atlas is shared by the material family; it is not a microscopy record of this exact selection. The approved sample and current supplier documents govern final colour and construction.

Grey Microcement Finish — Surface macro: natural fibre and controlled seam
01 Surface macro: natural fibre and controlled seam
Grey Microcement Finish — Construction edge: panel, backing and service cavity
02 Construction edge: panel, backing and service cavity
Grey Microcement Finish — Workshop control: datum, alignment and fixing
03 Workshop control: datum, alignment and fixing
Grey Microcement Finish — Application view: completed coordinated wall system
04 Application view: completed coordinated wall system

Material identity

What is unique—and what is shared with the family.

The exact material fingerprint comes first. Shared family science is explicitly separated in a collapsible appendix instead of being presented as unique content.

50 material-specific points · 40 shared family references

01 · Material fingerprint

What makes this exact selection technically distinct?

Position in the material family

Seamless mineral finish

Grey Microcement Finish Current material reference
AGrey Microcement Finish · Approx. 2–3 mm layered mineral/resin system over prepared substrate
Wall Coverings — Surface macro: natural fibre and controlled seam
B Surface macro: natural fibre and controlled seam
Reference that must be declared
Grey microcement layered mineral/resin system, typically about 2–3 mm only where selected manufacturer confirms; substrate and sealer included.
Selection differentiator
Continuous hand-trowelled tonal movement across walls, joinery and selected furniture.
Not an equivalent substitute
Cement paint, polished plaster and another microcement brand are not equivalent layered systems.
Reject the delivery when
Reject substrate read-through, hairline cracking, dark water patches, trowel burns, pinholes or visible patch repair outside control.

Shared family reference

Open the shared Wall Coverings engineering appendix

This appendix applies to the complete Wall Coverings family. It is retained as supporting reference and is not counted as unique content for this material.

02 · System anatomy

The material is not a single surface.

A thin layered mineral/resin microcement finish—typically about 2–3 mm—over a prepared stable substrate, completed with compatible sealer/topcoat. It is a system, not a standalone cement colour.

Wall Coverings — Construction edge: panel, backing and service cavity
01 Construction edge: panel, backing and service cavity
01 Visible finish
02 Carrier / panel
03 Adhesive / subframe
04 Building substrate

01Visible finish

Layer function

Natural fibre, felt, timber flute or mineral topcoat determines appearance, touch and cleanability.

How to verify

Approve a full-height installed finish under final lighting.

02Carrier / panel

Layer function

Backing, acoustic panel, veneered core or reinforced base distributes the finish and controls stability.

How to verify

Declare composition, thickness, density and relevant emissions/fire route.

03Adhesive / subframe

Layer function

Paste, adhesive, clips, battens, rails or mesh connect the finish and can change fire/acoustic behaviour.

How to verify

Shop drawing and test evidence must show the same mounting assembly.

04Building substrate

Layer function

Moisture, flatness, cracks, movement, joints and contamination transfer through the finished system.

How to verify

Complete substrate moisture/flatness hold point before installation.

03 · Decision gates

Reference benchmarks and the project rule.

Wall Coverings — Surface macro: natural fibre and controlled seam
V Surface macro: natural fibre and controlled seam

System identity

01
Reference band
Face, backing/panel, adhesive/subframe, joints, edge and substrate preparation declared together.
Project rule
Face-material data alone is not a system submittal.
Evidence status
Complete build-up and installation method

Reaction to fire

02
Reference band
Project/occupancy-specific and dependent on the complete tested build-up.
Project rule
Match face, backing, adhesive, substrate and mounting represented by evidence.
Evidence status
Current system test/classification

Acoustic absorption

03
Reference band
ISO 354 measures reverberation-room absorption of an installed material/assembly.
Project rule
State thickness, density, coverage, air gap, backing and mounting; do not quote face felt alone.
Evidence status
Test report for matching assembly

Substrate readiness

04
Reference band
Dry, stable, clean, level and compatible; quantitative moisture/flatness limits come from selected system.
Project rule
Record readings and repairs before covering evidence.
Evidence status
Substrate inspection sheet

Joint / layout

05
Reference band
Seam, panel, flute, control-joint and perimeter strategy coordinated on full elevations.
Project rule
Never hide building movement joints without an approved system detail.
Evidence status
Setting-out drawings and mock-up

Cleaning / impact

06
Reference band
Scrubbability, stain, edge impact, replaceability and patch visibility are finish specific.
Project rule
Trial actual cleaning and a deliberate repair on the mock-up.
Evidence status
Clean/impact/repair trial

04 · Family comparison

Four visually related systems that are not technically equivalent.

Grey Microcement Finish Material alternative
01Grey Microcement Finish
Type II Vinyl Wallcovering Material alternative
02Type II Vinyl Wallcovering
Natural Grasscloth Wallcovering Material alternative
03Natural Grasscloth Wallcovering
Acoustic Felt Wall Panels Material alternative
04Acoustic Felt Wall Panels
01

Natural roll wallcovering

Best use
Dry feature walls where fibre, visible seams and handmade variation are desired.
Trade-off / constraint
Moisture, paste staining, impact and wet cleaning are constrained.
02

Acoustic felt panel

Best use
Rooms requiring controlled reverberation plus colour and modular replacement.
Trade-off / constraint
Performance belongs to tested thickness, air gap, coverage and mounting.
03

Fluted timber panel

Best use
Architectural feature walls integrating grain, rhythm, access and joinery.
Trade-off / constraint
Module set-out, substrate, emissions, fire route and movement require coordination.
04 Current classification

Seamless mineral finish

Best use
Continuous hand-trowelled walls and furniture with controlled tonal movement.
Trade-off / constraint
Thin finish cannot bridge substrate cracks, failed waterproofing or movement joints.
05

Commercial vinyl wallcovering

Best use
Guestrooms and corridors requiring repeatable texture, impact resistance and routine cleaning.
Trade-off / constraint
Moisture migration, trapped vapour, seam quality, plasticiser and adhesive compatibility remain system risks.

05 · Factory handbook

Hold points from receiving through production release.

Fabrication focus for this exact material

Repair cracks, honour movement joints, reinforce as required and apply one manufacturer’s full cure/sealer sequence.

Wall Coverings — Workshop control: datum, alignment and fixing
05 Workshop control: datum, alignment and fixing
  1. 01Substrate survey

    Control instruction

    Record material, moisture, pH where relevant, flatness, cracks, joints, contaminants and repairs.

    Close-out evidence

    Signed hold-point sheet and photographs

  2. 02Set-out

    Control instruction

    Coordinate seams/panels/flutes from one datum around corners, doors, outlets and service panels.

    Close-out evidence

    Full elevations with numbered modules/drops

  3. 03Compatibility trial

    Control instruction

    Apply primer, adhesive/subframe, finish and edge on the actual prepared substrate.

    Close-out evidence

    Cured trial checked for bond, stain, read-through and removal/repair

  4. 04Full-height mock-up

    Control instruction

    Include corner, joint, termination, outlet, impact edge, lighting and deliberate cleaning/repair.

    Close-out evidence

    Signed minimum/maximum appearance controls

  5. 05Area release

    Control instruction

    Sequence batch/roll/panel, protect completed work and stop after first area for inspection.

    Close-out evidence

    First-area acceptance before repetitive installation

06 · Climate & operations

GCC exposure matrix and maintenance plan.

Material-specific climate warning

Wet areas depend on underlying waterproofing; hot dry application can shorten working time and alter colour.

Wall Coverings — Application view: completed coordinated wall system
06 Application view: completed coordinated wall system

01Guestroom feature wall

Preferred
Material response
Controlled use suits most systems if luggage impact, cleaning and replacement are resolved.
Design control
Use protected edges and retain matching repair stock.

02Corridor / lobby

Conditional
Material response
Trolley impact, hand contact, wall washing and fire requirements intensify.
Design control
Select contract surface/system and prove impact/cleaning at the mock-up.

03Restaurant

Conditional
Material response
Food soils, grease aerosols, chair impact and frequent cleaning challenge porous/textural finishes.
Design control
Use washable, repairable zones or protective dados at high contact.

04Window / façade wall

Conditional
Material response
Solar heat and façade condensation can drive movement, fading or concealed moisture.
Design control
Investigate envelope moisture and require suitable light/temperature performance.

05Wet area

Avoid
Material response
Water and vapour attack backing, adhesive, timber core and unsealed joints.
Design control
Use only a complete wet-area-approved system over proven waterproofing.

06Exterior / semi-exterior

Avoid
Material response
Interior wall systems generally lack UV, rain, thermal and wind-load design.
Design control
Require a purpose-designed exterior assembly and engineering.

Operational maintenance plan

Material-specific care rule

Use sealer-compatible neutral cleaner and renew topcoat by condition, not a generic calendar.

  1. 01Daily / weekly

    Action

    Remove surface dust with the approved dry or low-moisture method.

    Prohibited

    No wet wiping on natural fibre or unapproved felt/wood.

  2. 02After a mark

    Action

    Identify finish and soil, then use the specific spot-clean or touch-up route.

    Prohibited

    No aggressive rubbing that polishes, frays or burnishes texture.

  3. 03Monthly

    Action

    Inspect seams, corners, edges, impact zones, bubbles, cracks, moisture and loose modules.

    Prohibited

    Do not close or paint over unexplained moisture.

  4. 04Periodic deep clean

    Action

    Use only the manufacturer-approved system and test on a retained/hidden sample.

    Prohibited

    No generic steam or extraction cleaning.

  5. 05Repair / replacement

    Action

    Replace complete drops/modules where practical or reproduce the recorded layered repair method.

    Prohibited

    Do not promise invisible patches on natural or hand-applied finishes.

07 · Reference library

The language that governs the decision—and where it comes from.

Wall Coverings — Surface macro: natural fibre and controlled seam
01 Surface macro: natural fibre and controlled seam
Wall Coverings — Construction edge: panel, backing and service cavity
02 Construction edge: panel, backing and service cavity
Wall Coverings — Workshop control: datum, alignment and fixing
03 Workshop control: datum, alignment and fixing
Wall Coverings — Application view: completed coordinated wall system
04 Application view: completed coordinated wall system

Material glossary

01Substrate
The wall or supporting surface receiving the finish system.
02Drop
One full-height length of roll wallcovering.
03NRC / αw
Single-number acoustic absorption ratings derived under defined test and assembly conditions.
04Air gap
Space behind an acoustic panel that can materially change absorption performance.
05Read-through
Visible transfer of joints, defects, adhesive or substrate texture through the finish.

Professional and standards sources

  1. 01

    ISO

    ISO 354 acoustic absorption

    Reverberation-room method for wall/ceiling materials and complete assemblies.

    Open primary source ↗
  2. 02

    BSI

    BS EN 15102 decorative wallcoverings

    Roll-wallcovering characteristics including fire and dangerous-substance declarations.

    Open primary source ↗
  3. 03

    Wallcoverings Association

    Wallcovering quality standards

    Industry attributes including strength, tear, fire, UV, stain and scrubbability.

    Open primary source ↗
  4. 04

    Wallcoverings Association

    Standard installation guidance

    Roll/lot control, panel sequence, adhesive, seams, lighting and stop-work checks.

    Open primary source ↗

Material-specific technical dossier

Grey Microcement Finish controls from decision to production.

Every row below is tied to this material’s identity, differentiator, fabrication, exposure or care route; no generic family rows are included in this dossier.

8 unique controls · 4 contextual test applications · 5 material-specific risks

System definition

A thin layered mineral/resin microcement finish—typically about 2–3 mm—over a prepared stable substrate, completed with compatible sealer/topcoat. It is a system, not a standalone cement colour.

Critical decision

The substrate and waterproofing carry movement/water control. Microcement cannot bridge unresolved cracks, joints or failed wet-area waterproofing.

01 · Selection variables

What the material schedule must lock.

Grey Microcement Finish Current material reference
Approx. 2–3 mm layered mineral/resin system over prepared substrate

01Grey Microcement Finish: Layered system

What must be declared
Primer, reinforcement mesh where required, base coats, finish coats, sealer/topcoat and total build
Approval basis
One manufacturer/system warranty covers all layers and substrate route.

02Grey Microcement Finish: Movement & waterproofing

What must be declared
Existing cracks, control joints, deflection, wet-area membrane, penetrations and terminations
Approval basis
Substrate hold point and waterproofing test are complete before finish.

03Grey Microcement Finish: identity declaration

What must be declared
Grey microcement layered mineral/resin system, typically about 2–3 mm only where selected manufacturer confirms; substrate and sealer included.
Approval basis
The substrate and waterproofing carry movement/water control. Microcement cannot bridge unresolved cracks, joints or failed wet-area waterproofing.

04Grey Microcement Finish: equivalency boundary

What must be declared
Continuous hand-trowelled tonal movement across walls, joinery and selected furniture.
Approval basis
Cement paint, polished plaster and another microcement brand are not equivalent layered systems.

05Grey Microcement Finish: factory execution

What must be declared
Repair cracks, honour movement joints, reinforce as required and apply one manufacturer’s full cure/sealer sequence.
Approval basis
One manufacturer/system warranty covers all layers and substrate route.

06Grey Microcement Finish: GCC exposure control

What must be declared
Wet areas depend on underlying waterproofing; hot dry application can shorten working time and alter colour.
Approval basis
Release only when the project detail and maintenance route close this exact exposure risk for Grey Microcement Finish.

07Grey Microcement Finish: operational care route

What must be declared
Use sealer-compatible neutral cleaner and renew topcoat by condition, not a generic calendar.
Approval basis
Issue a named cleaning and repair method for Grey Microcement Finish; generic family care is not approval.

08Grey Microcement Finish: delivery rejection boundary

What must be declared
Reject substrate read-through, hairline cracking, dark water patches, trowel burns, pinholes or visible patch repair outside control.
Approval basis
The signed sample, first-off item and delivery inspection must all close this rejection condition for Grey Microcement Finish.

02 · Verification

Test and evidence matrix.

Test methods are not compliance certificates or automatic pass values. The project must state the method, required result, tested construction and current report it will accept.

Wall Coverings — Construction edge: panel, backing and service cavity
02 Construction edge: panel, backing and service cavity

BS EN 15102:2019

01
What it measures
Product requirements for decorative wallcoverings in roll form.
How to use it here
Apply to relevant roll wallcoverings and review fire, substance, durability and declared characteristics for the actual product. Material-specific acceptance for Grey Microcement Finish: One manufacturer/system warranty covers all layers and substrate route.
Official reference ↗

ISO 354:2003

02
What it measures
Reverberation-room measurement of sound absorption for wall/ceiling treatments.
How to use it here
Acoustic claim belongs to the tested assembly, area and mounting—not the face material alone. Material-specific acceptance for Grey Microcement Finish: Substrate hold point and waterproofing test are complete before finish.
Official reference ↗

Project reaction-to-fire route

03
What it measures
Classification/test evidence for the complete installed wall system.
How to use it here
Match product, substrate, adhesive, subframe/air gap and end-use orientation. Material-specific acceptance for Grey Microcement Finish: Repair/stabilise substrate, honour joints and test full system including sealer.

Installed project mock-up

04
What it measures
Visual, dimensional, cleanability and repair verification in real substrate and lighting.
How to use it here
Include a corner, seam/joint, opening, termination and representative cleaning test. Material-specific acceptance for Grey Microcement Finish: Repair cracks, honour movement joints, reinforce as required and apply one manufacturer’s full cure/sealer sequence.

03 · Performance

Failure-mode and control register.

Grey Microcement Finish applied to its dedicated furniture product
Grey Microcement Finish applied to its dedicated furniture product

01Grey Microcement Finish: Hairline cracks or dark water patches

Likely cause
Substrate movement transfers through thin finish or sealer/waterproofing is incomplete.
Preventive control
Repair/stabilise substrate, honour joints and test full system including sealer.

02Grey Microcement Finish: non-equivalent substitution accepted

Likely cause
Cement paint, polished plaster and another microcement brand are not equivalent layered systems.
Preventive control
Grey microcement layered mineral/resin system, typically about 2–3 mm only where selected manufacturer confirms; substrate and sealer included.

03Grey Microcement Finish: material signature lost in fabrication

Likely cause
The workshop route does not implement the material-specific fabrication focus: Repair cracks, honour movement joints, reinforce as required and apply one manufacturer’s full cure/sealer sequence.
Preventive control
Substrate hold point and waterproofing test are complete before finish.

04Grey Microcement Finish: GCC exposure mismatch

Likely cause
Wet areas depend on underlying waterproofing; hot dry application can shorten working time and alter colour.
Preventive control
Re-detail, relocate or reject Grey Microcement Finish where the stated exposure cannot be controlled.

05Grey Microcement Finish: cleaning or maintenance damage

Likely cause
Use sealer-compatible neutral cleaner and renew topcoat by condition, not a generic calendar.
Preventive control
Train operations on the named care route and retain a signed repair reference for Grey Microcement Finish.

04 · Tender-ready

Copy-ready specification clause.

Provide grey microcement as one manufacturer’s complete layered system over an approved stable substrate: primer, reinforcement where required, base/finish coats and compatible sealer/topcoat, approximately 2–3 mm only where confirmed by the selected system. Submit substrate criteria, moisture/movement limits, wet-area waterproofing interface, layer build, cure, slip/stain/cleaner data where relevant, reaction-to-fire evidence and repair method. Approve a full-height/area mock-up including joint, corner, penetration, water exposure and deliberate patch repair.

05 · Quality control

Inspection plan from submittal to handover.

Wall Coverings — Workshop control: datum, alignment and fixing
05 Workshop control: datum, alignment and fixing

01Grey Microcement Finish: identity and source

Inspection
Grey microcement layered mineral/resin system, typically about 2–3 mm only where selected manufacturer confirms; substrate and sealer included.
Acceptance / hold point
Documents, labels and physical material all identify the same Grey Microcement Finish construction and source.

02Grey Microcement Finish: control sample

Inspection
Continuous hand-trowelled tonal movement across walls, joinery and selected furniture.
Acceptance / hold point
One manufacturer/system warranty covers all layers and substrate route.

03Grey Microcement Finish: first-off fabrication

Inspection
Repair cracks, honour movement joints, reinforce as required and apply one manufacturer’s full cure/sealer sequence.
Acceptance / hold point
Substrate hold point and waterproofing test are complete before finish.

04Grey Microcement Finish: exposure and care trial

Inspection
Wet areas depend on underlying waterproofing; hot dry application can shorten working time and alter colour. Use sealer-compatible neutral cleaner and renew topcoat by condition, not a generic calendar.
Acceptance / hold point
Repair/stabilise substrate, honour joints and test full system including sealer.

05Grey Microcement Finish: delivery release

Inspection
Reject substrate read-through, hairline cracking, dark water patches, trowel burns, pinholes or visible patch repair outside control.
Acceptance / hold point
Grey Microcement Finish is released only when no stated rejection condition is present and the signed reference remains traceable.

Required approval evidence

  • +Grey Microcement Finish: Identity/source evidence: Grey microcement layered mineral/resin system, typically about 2–3 mm only where selected manufacturer confirms; substrate and sealer included.
  • +Grey Microcement Finish: Signed selection evidence: One manufacturer/system warranty covers all layers and substrate route.
  • +Grey Microcement Finish: Second technical gate: Substrate hold point and waterproofing test are complete before finish.
  • +Grey Microcement Finish: Factory close-out: Repair cracks, honour movement joints, reinforce as required and apply one manufacturer’s full cure/sealer sequence.
  • +Grey Microcement Finish: Exposure and care record: Wet areas depend on underlying waterproofing; hot dry application can shorten working time and alter colour. Use sealer-compatible neutral cleaner and renew topcoat by condition, not a generic calendar.
  • +Grey Microcement Finish: Delivery rejection record: Reject substrate read-through, hairline cracking, dark water patches, trowel burns, pinholes or visible patch repair outside control.

Questions to close before approval

  1. 01Grey Microcement Finish: Has the exact identity been declared and evidenced: Grey microcement layered mineral/resin system, typically about 2–3 mm only where selected manufacturer confirms; substrate and sealer included?
  2. 02Grey Microcement Finish: Which project requirement makes this differentiator necessary: Continuous hand-trowelled tonal movement across walls, joinery and selected furniture?
  3. 03Grey Microcement Finish: Has the team excluded the non-equivalent route: Cement paint, polished plaster and another microcement brand are not equivalent layered systems?
  4. 04Grey Microcement Finish: How will the factory prove this execution control: Repair cracks, honour movement joints, reinforce as required and apply one manufacturer’s full cure/sealer sequence?
  5. 05Grey Microcement Finish: Can the project control this GCC exposure: Wet areas depend on underlying waterproofing; hot dry application can shorten working time and alter colour?
  6. 06Grey Microcement Finish: Who owns this operating rule after handover: Use sealer-compatible neutral cleaner and renew topcoat by condition, not a generic calendar?

Exact material application

Grey Microcement Finish on a dedicated furniture product.

This material-specific application image shows Grey Microcement Finish on its own product and is not reused by any other material page. Final colour, pattern and finish remain subject to the approved physical sample.

Grey Microcement Finish applied to its dedicated furniture product
01Grey Microcement Finish applied to its dedicated furniture product

Project notes

From sample to production.

01

What to specify

Select after confirming substrate, fire requirement, cleaning, acoustics, humidity and joint layout. A full installed mock-up is the most reliable approval reference.

02

Fabrication & detailing

Survey substrates and coordinate setting-out with doors, outlets, lighting and joinery. Complete a mock-up before bulk installation and protect finished work from following trades.

03

Colour & finish approval

Wall finishes are approved as installed mock-ups because lighting, substrate, panel joints and hand application materially change the final appearance.

04

Care & maintenance

Follow the approved maintenance guide for the selected system. Dust or spot-clean gently; repair test areas first so colour, sheen and texture remain consistent.

Specification note

This page is a preliminary specification guide. No value, brand reference or material name constitutes automatic compliance. Current product data, test reports, physical sample or slab and the furniture construction must be approved for each project before ordering or manufacture.

Request an approval sample for Grey Microcement Finish

Share the material schedule, furniture item, quantity and project location. We will confirm the sample, furniture construction and technical documents required for approval.