Wall Coverings · Furniture specification
Grey Microcement Finish Furniture Specifications
Grey Microcement Finish for hotel guestrooms, corridors, lobbies and feature joinery, selected as a complete installed system rather than by surface colour alone.
Current material reference
Approx. 2–3 mm layered mineral/resin system over prepared substrate
Project-specific system · final build-up must be tested
Material decision summary
Project suitability at a glance.
Treat the finish, substrate, adhesive or subframe, joints and installation method as one tested system.
Best for
- +Seamless feature surfaces where substrate preparation and sealer can be controlled
Avoid when
- −Movement joints, waterproofing or future patch variation cannot be managed
- Traffic level
- High
- Maintenance
- Medium
- Visual variation
- Medium
- Relative budget
- ●●●○
- Suitable environments
- Interior · High traffic · Wet area
Material overview
Most requested furniture applications
Select after confirming substrate, fire requirement, cleaning, acoustics, humidity and joint layout. A full installed mock-up is the most reliable approval reference.
Material-specific authority schedule
Ten controls owned by this exact material—not inherited category rows. Final values are confirmed from supplier data, the project sample and shop drawings.


- Declared project reference
- Grey Microcement Finish: Approx. 2–3 mm layered mineral/resin system over prepared substrate
- Exact material identity
- Grey microcement layered mineral/resin system, typically about 2–3 mm only where selected manufacturer confirms; substrate and sealer included.
- Technical system definition
- A thin layered mineral/resin microcement finish—typically about 2–3 mm—over a prepared stable substrate, completed with compatible sealer/topcoat. It is a system, not a standalone cement colour.
- Selection differentiator
- Continuous hand-trowelled tonal movement across walls, joinery and selected furniture.
- Critical approval decision
- The substrate and waterproofing carry movement/water control. Microcement cannot bridge unresolved cracks, joints or failed wet-area waterproofing.
- Non-equivalent substitute
- Cement paint, polished plaster and another microcement brand are not equivalent layered systems.
- Fabrication focus
- Repair cracks, honour movement joints, reinforce as required and apply one manufacturer’s full cure/sealer sequence.
- GCC exposure limit
- Wet areas depend on underlying waterproofing; hot dry application can shorten working time and alter colour.
- Material-specific care rule
- Use sealer-compatible neutral cleaner and renew topcoat by condition, not a generic calendar.
- Reject the delivery when
- Reject substrate read-through, hairline cracking, dark water patches, trowel burns, pinholes or visible patch repair outside control.
Approval pack
Documents required before ordering.
Project-specific system · final build-up must be tested
- Grey Microcement Finish: Identity/source evidence: Grey microcement layered mineral/resin system, typically about 2–3 mm only where selected manufacturer confirms; substrate and sealer included.
- Grey Microcement Finish: Signed selection evidence: One manufacturer/system warranty covers all layers and substrate route.
- Grey Microcement Finish: Second technical gate: Substrate hold point and waterproofing test are complete before finish.
- Grey Microcement Finish: Factory close-out: Repair cracks, honour movement joints, reinforce as required and apply one manufacturer’s full cure/sealer sequence.
Lead time & availability
Confirmed after source, finish and quantity selection
Family inspection atlas
A shared visual reference for construction and fabrication.
This atlas is shared by the material family; it is not a microscopy record of this exact selection. The approved sample and current supplier documents govern final colour and construction.
Material identity
What is unique—and what is shared with the family.
The exact material fingerprint comes first. Shared family science is explicitly separated in a collapsible appendix instead of being presented as unique content.
50 material-specific points · 40 shared family references
01 · Material fingerprint
What makes this exact selection technically distinct?
Position in the material family
Seamless mineral finish

- Reference that must be declared
- Grey microcement layered mineral/resin system, typically about 2–3 mm only where selected manufacturer confirms; substrate and sealer included.
- Selection differentiator
- Continuous hand-trowelled tonal movement across walls, joinery and selected furniture.
- Not an equivalent substitute
- Cement paint, polished plaster and another microcement brand are not equivalent layered systems.
- Reject the delivery when
- Reject substrate read-through, hairline cracking, dark water patches, trowel burns, pinholes or visible patch repair outside control.
Shared family reference
Open the shared Wall Coverings engineering appendix
This appendix applies to the complete Wall Coverings family. It is retained as supporting reference and is not counted as unique content for this material.
Shared family reference
Open the shared Wall Coverings engineering appendix
This appendix applies to the complete Wall Coverings family. It is retained as supporting reference and is not counted as unique content for this material.
02 · System anatomy
The material is not a single surface.
A thin layered mineral/resin microcement finish—typically about 2–3 mm—over a prepared stable substrate, completed with compatible sealer/topcoat. It is a system, not a standalone cement colour.
01Visible finish
Layer function
Natural fibre, felt, timber flute or mineral topcoat determines appearance, touch and cleanability.
How to verify
Approve a full-height installed finish under final lighting.
02Carrier / panel
Layer function
Backing, acoustic panel, veneered core or reinforced base distributes the finish and controls stability.
How to verify
Declare composition, thickness, density and relevant emissions/fire route.
03Adhesive / subframe
Layer function
Paste, adhesive, clips, battens, rails or mesh connect the finish and can change fire/acoustic behaviour.
How to verify
Shop drawing and test evidence must show the same mounting assembly.
04Building substrate
Layer function
Moisture, flatness, cracks, movement, joints and contamination transfer through the finished system.
How to verify
Complete substrate moisture/flatness hold point before installation.
03 · Decision gates
Reference benchmarks and the project rule.
System identity
01- Reference band
- Face, backing/panel, adhesive/subframe, joints, edge and substrate preparation declared together.
- Project rule
- Face-material data alone is not a system submittal.
- Evidence status
- Complete build-up and installation method
Reaction to fire
02- Reference band
- Project/occupancy-specific and dependent on the complete tested build-up.
- Project rule
- Match face, backing, adhesive, substrate and mounting represented by evidence.
- Evidence status
- Current system test/classification
Acoustic absorption
03- Reference band
- ISO 354 measures reverberation-room absorption of an installed material/assembly.
- Project rule
- State thickness, density, coverage, air gap, backing and mounting; do not quote face felt alone.
- Evidence status
- Test report for matching assembly
Substrate readiness
04- Reference band
- Dry, stable, clean, level and compatible; quantitative moisture/flatness limits come from selected system.
- Project rule
- Record readings and repairs before covering evidence.
- Evidence status
- Substrate inspection sheet
Joint / layout
05- Reference band
- Seam, panel, flute, control-joint and perimeter strategy coordinated on full elevations.
- Project rule
- Never hide building movement joints without an approved system detail.
- Evidence status
- Setting-out drawings and mock-up
Cleaning / impact
06- Reference band
- Scrubbability, stain, edge impact, replaceability and patch visibility are finish specific.
- Project rule
- Trial actual cleaning and a deliberate repair on the mock-up.
- Evidence status
- Clean/impact/repair trial
04 · Family comparison
Four visually related systems that are not technically equivalent.




Natural roll wallcovering
- Best use
- Dry feature walls where fibre, visible seams and handmade variation are desired.
- Trade-off / constraint
- Moisture, paste staining, impact and wet cleaning are constrained.
Acoustic felt panel
- Best use
- Rooms requiring controlled reverberation plus colour and modular replacement.
- Trade-off / constraint
- Performance belongs to tested thickness, air gap, coverage and mounting.
Fluted timber panel
- Best use
- Architectural feature walls integrating grain, rhythm, access and joinery.
- Trade-off / constraint
- Module set-out, substrate, emissions, fire route and movement require coordination.
Seamless mineral finish
- Best use
- Continuous hand-trowelled walls and furniture with controlled tonal movement.
- Trade-off / constraint
- Thin finish cannot bridge substrate cracks, failed waterproofing or movement joints.
Commercial vinyl wallcovering
- Best use
- Guestrooms and corridors requiring repeatable texture, impact resistance and routine cleaning.
- Trade-off / constraint
- Moisture migration, trapped vapour, seam quality, plasticiser and adhesive compatibility remain system risks.
05 · Factory handbook
Hold points from receiving through production release.
Fabrication focus for this exact material
Repair cracks, honour movement joints, reinforce as required and apply one manufacturer’s full cure/sealer sequence.
-
01Substrate survey
Control instruction
Record material, moisture, pH where relevant, flatness, cracks, joints, contaminants and repairs.
Close-out evidence
Signed hold-point sheet and photographs
-
02Set-out
Control instruction
Coordinate seams/panels/flutes from one datum around corners, doors, outlets and service panels.
Close-out evidence
Full elevations with numbered modules/drops
-
03Compatibility trial
Control instruction
Apply primer, adhesive/subframe, finish and edge on the actual prepared substrate.
Close-out evidence
Cured trial checked for bond, stain, read-through and removal/repair
-
04Full-height mock-up
Control instruction
Include corner, joint, termination, outlet, impact edge, lighting and deliberate cleaning/repair.
Close-out evidence
Signed minimum/maximum appearance controls
-
05Area release
Control instruction
Sequence batch/roll/panel, protect completed work and stop after first area for inspection.
Close-out evidence
First-area acceptance before repetitive installation
06 · Climate & operations
GCC exposure matrix and maintenance plan.
Material-specific climate warning
Wet areas depend on underlying waterproofing; hot dry application can shorten working time and alter colour.
01Guestroom feature wall
Preferred- Material response
- Controlled use suits most systems if luggage impact, cleaning and replacement are resolved.
- Design control
- Use protected edges and retain matching repair stock.
02Corridor / lobby
Conditional- Material response
- Trolley impact, hand contact, wall washing and fire requirements intensify.
- Design control
- Select contract surface/system and prove impact/cleaning at the mock-up.
03Restaurant
Conditional- Material response
- Food soils, grease aerosols, chair impact and frequent cleaning challenge porous/textural finishes.
- Design control
- Use washable, repairable zones or protective dados at high contact.
04Window / façade wall
Conditional- Material response
- Solar heat and façade condensation can drive movement, fading or concealed moisture.
- Design control
- Investigate envelope moisture and require suitable light/temperature performance.
05Wet area
Avoid- Material response
- Water and vapour attack backing, adhesive, timber core and unsealed joints.
- Design control
- Use only a complete wet-area-approved system over proven waterproofing.
06Exterior / semi-exterior
Avoid- Material response
- Interior wall systems generally lack UV, rain, thermal and wind-load design.
- Design control
- Require a purpose-designed exterior assembly and engineering.
Operational maintenance plan
Material-specific care rule
Use sealer-compatible neutral cleaner and renew topcoat by condition, not a generic calendar.
-
01Daily / weekly
Action
Remove surface dust with the approved dry or low-moisture method.
Prohibited
No wet wiping on natural fibre or unapproved felt/wood.
-
02After a mark
Action
Identify finish and soil, then use the specific spot-clean or touch-up route.
Prohibited
No aggressive rubbing that polishes, frays or burnishes texture.
-
03Monthly
Action
Inspect seams, corners, edges, impact zones, bubbles, cracks, moisture and loose modules.
Prohibited
Do not close or paint over unexplained moisture.
-
04Periodic deep clean
Action
Use only the manufacturer-approved system and test on a retained/hidden sample.
Prohibited
No generic steam or extraction cleaning.
-
05Repair / replacement
Action
Replace complete drops/modules where practical or reproduce the recorded layered repair method.
Prohibited
Do not promise invisible patches on natural or hand-applied finishes.
07 · Reference library
The language that governs the decision—and where it comes from.
Material glossary
- 01Substrate
- The wall or supporting surface receiving the finish system.
- 02Drop
- One full-height length of roll wallcovering.
- 03NRC / αw
- Single-number acoustic absorption ratings derived under defined test and assembly conditions.
- 04Air gap
- Space behind an acoustic panel that can materially change absorption performance.
- 05Read-through
- Visible transfer of joints, defects, adhesive or substrate texture through the finish.
Professional and standards sources
- 01
ISO
ISO 354 acoustic absorption
Reverberation-room method for wall/ceiling materials and complete assemblies.
Open primary source ↗ - 02
BSI
BS EN 15102 decorative wallcoverings
Roll-wallcovering characteristics including fire and dangerous-substance declarations.
Open primary source ↗ - 03
Wallcoverings Association
Wallcovering quality standards
Industry attributes including strength, tear, fire, UV, stain and scrubbability.
Open primary source ↗ - 04
Wallcoverings Association
Standard installation guidance
Roll/lot control, panel sequence, adhesive, seams, lighting and stop-work checks.
Open primary source ↗
Material-specific technical dossier
Grey Microcement Finish controls from decision to production.
Every row below is tied to this material’s identity, differentiator, fabrication, exposure or care route; no generic family rows are included in this dossier.
8 unique controls · 4 contextual test applications · 5 material-specific risks
System definition
A thin layered mineral/resin microcement finish—typically about 2–3 mm—over a prepared stable substrate, completed with compatible sealer/topcoat. It is a system, not a standalone cement colour.
Critical decision
The substrate and waterproofing carry movement/water control. Microcement cannot bridge unresolved cracks, joints or failed wet-area waterproofing.
01 · Selection variables
What the material schedule must lock.

01Grey Microcement Finish: Layered system
- What must be declared
- Primer, reinforcement mesh where required, base coats, finish coats, sealer/topcoat and total build
- Approval basis
- One manufacturer/system warranty covers all layers and substrate route.
02Grey Microcement Finish: Movement & waterproofing
- What must be declared
- Existing cracks, control joints, deflection, wet-area membrane, penetrations and terminations
- Approval basis
- Substrate hold point and waterproofing test are complete before finish.
03Grey Microcement Finish: identity declaration
- What must be declared
- Grey microcement layered mineral/resin system, typically about 2–3 mm only where selected manufacturer confirms; substrate and sealer included.
- Approval basis
- The substrate and waterproofing carry movement/water control. Microcement cannot bridge unresolved cracks, joints or failed wet-area waterproofing.
04Grey Microcement Finish: equivalency boundary
- What must be declared
- Continuous hand-trowelled tonal movement across walls, joinery and selected furniture.
- Approval basis
- Cement paint, polished plaster and another microcement brand are not equivalent layered systems.
05Grey Microcement Finish: factory execution
- What must be declared
- Repair cracks, honour movement joints, reinforce as required and apply one manufacturer’s full cure/sealer sequence.
- Approval basis
- One manufacturer/system warranty covers all layers and substrate route.
06Grey Microcement Finish: GCC exposure control
- What must be declared
- Wet areas depend on underlying waterproofing; hot dry application can shorten working time and alter colour.
- Approval basis
- Release only when the project detail and maintenance route close this exact exposure risk for Grey Microcement Finish.
07Grey Microcement Finish: operational care route
- What must be declared
- Use sealer-compatible neutral cleaner and renew topcoat by condition, not a generic calendar.
- Approval basis
- Issue a named cleaning and repair method for Grey Microcement Finish; generic family care is not approval.
08Grey Microcement Finish: delivery rejection boundary
- What must be declared
- Reject substrate read-through, hairline cracking, dark water patches, trowel burns, pinholes or visible patch repair outside control.
- Approval basis
- The signed sample, first-off item and delivery inspection must all close this rejection condition for Grey Microcement Finish.
| Variable | What must be declared | Approval basis |
|---|---|---|
| 01Grey Microcement Finish: Layered system | Primer, reinforcement mesh where required, base coats, finish coats, sealer/topcoat and total build | One manufacturer/system warranty covers all layers and substrate route. |
| 02Grey Microcement Finish: Movement & waterproofing | Existing cracks, control joints, deflection, wet-area membrane, penetrations and terminations | Substrate hold point and waterproofing test are complete before finish. |
| 03Grey Microcement Finish: identity declaration | Grey microcement layered mineral/resin system, typically about 2–3 mm only where selected manufacturer confirms; substrate and sealer included. | The substrate and waterproofing carry movement/water control. Microcement cannot bridge unresolved cracks, joints or failed wet-area waterproofing. |
| 04Grey Microcement Finish: equivalency boundary | Continuous hand-trowelled tonal movement across walls, joinery and selected furniture. | Cement paint, polished plaster and another microcement brand are not equivalent layered systems. |
| 05Grey Microcement Finish: factory execution | Repair cracks, honour movement joints, reinforce as required and apply one manufacturer’s full cure/sealer sequence. | One manufacturer/system warranty covers all layers and substrate route. |
| 06Grey Microcement Finish: GCC exposure control | Wet areas depend on underlying waterproofing; hot dry application can shorten working time and alter colour. | Release only when the project detail and maintenance route close this exact exposure risk for Grey Microcement Finish. |
| 07Grey Microcement Finish: operational care route | Use sealer-compatible neutral cleaner and renew topcoat by condition, not a generic calendar. | Issue a named cleaning and repair method for Grey Microcement Finish; generic family care is not approval. |
| 08Grey Microcement Finish: delivery rejection boundary | Reject substrate read-through, hairline cracking, dark water patches, trowel burns, pinholes or visible patch repair outside control. | The signed sample, first-off item and delivery inspection must all close this rejection condition for Grey Microcement Finish. |
02 · Verification
Test and evidence matrix.
Test methods are not compliance certificates or automatic pass values. The project must state the method, required result, tested construction and current report it will accept.
BS EN 15102:2019
01- What it measures
- Product requirements for decorative wallcoverings in roll form.
- How to use it here
- Apply to relevant roll wallcoverings and review fire, substance, durability and declared characteristics for the actual product. Material-specific acceptance for Grey Microcement Finish: One manufacturer/system warranty covers all layers and substrate route.
ISO 354:2003
02- What it measures
- Reverberation-room measurement of sound absorption for wall/ceiling treatments.
- How to use it here
- Acoustic claim belongs to the tested assembly, area and mounting—not the face material alone. Material-specific acceptance for Grey Microcement Finish: Substrate hold point and waterproofing test are complete before finish.
Project reaction-to-fire route
03- What it measures
- Classification/test evidence for the complete installed wall system.
- How to use it here
- Match product, substrate, adhesive, subframe/air gap and end-use orientation. Material-specific acceptance for Grey Microcement Finish: Repair/stabilise substrate, honour joints and test full system including sealer.
Installed project mock-up
04- What it measures
- Visual, dimensional, cleanability and repair verification in real substrate and lighting.
- How to use it here
- Include a corner, seam/joint, opening, termination and representative cleaning test. Material-specific acceptance for Grey Microcement Finish: Repair cracks, honour movement joints, reinforce as required and apply one manufacturer’s full cure/sealer sequence.
03 · Performance
Failure-mode and control register.

01Grey Microcement Finish: Hairline cracks or dark water patches
- Likely cause
- Substrate movement transfers through thin finish or sealer/waterproofing is incomplete.
- Preventive control
- Repair/stabilise substrate, honour joints and test full system including sealer.
02Grey Microcement Finish: non-equivalent substitution accepted
- Likely cause
- Cement paint, polished plaster and another microcement brand are not equivalent layered systems.
- Preventive control
- Grey microcement layered mineral/resin system, typically about 2–3 mm only where selected manufacturer confirms; substrate and sealer included.
03Grey Microcement Finish: material signature lost in fabrication
- Likely cause
- The workshop route does not implement the material-specific fabrication focus: Repair cracks, honour movement joints, reinforce as required and apply one manufacturer’s full cure/sealer sequence.
- Preventive control
- Substrate hold point and waterproofing test are complete before finish.
04Grey Microcement Finish: GCC exposure mismatch
- Likely cause
- Wet areas depend on underlying waterproofing; hot dry application can shorten working time and alter colour.
- Preventive control
- Re-detail, relocate or reject Grey Microcement Finish where the stated exposure cannot be controlled.
05Grey Microcement Finish: cleaning or maintenance damage
- Likely cause
- Use sealer-compatible neutral cleaner and renew topcoat by condition, not a generic calendar.
- Preventive control
- Train operations on the named care route and retain a signed repair reference for Grey Microcement Finish.
| Failure mode | Likely cause | Preventive control |
|---|---|---|
| 01Grey Microcement Finish: Hairline cracks or dark water patches | Substrate movement transfers through thin finish or sealer/waterproofing is incomplete. | Repair/stabilise substrate, honour joints and test full system including sealer. |
| 02Grey Microcement Finish: non-equivalent substitution accepted | Cement paint, polished plaster and another microcement brand are not equivalent layered systems. | Grey microcement layered mineral/resin system, typically about 2–3 mm only where selected manufacturer confirms; substrate and sealer included. |
| 03Grey Microcement Finish: material signature lost in fabrication | The workshop route does not implement the material-specific fabrication focus: Repair cracks, honour movement joints, reinforce as required and apply one manufacturer’s full cure/sealer sequence. | Substrate hold point and waterproofing test are complete before finish. |
| 04Grey Microcement Finish: GCC exposure mismatch | Wet areas depend on underlying waterproofing; hot dry application can shorten working time and alter colour. | Re-detail, relocate or reject Grey Microcement Finish where the stated exposure cannot be controlled. |
| 05Grey Microcement Finish: cleaning or maintenance damage | Use sealer-compatible neutral cleaner and renew topcoat by condition, not a generic calendar. | Train operations on the named care route and retain a signed repair reference for Grey Microcement Finish. |
04 · Tender-ready
Copy-ready specification clause.
Provide grey microcement as one manufacturer’s complete layered system over an approved stable substrate: primer, reinforcement where required, base/finish coats and compatible sealer/topcoat, approximately 2–3 mm only where confirmed by the selected system. Submit substrate criteria, moisture/movement limits, wet-area waterproofing interface, layer build, cure, slip/stain/cleaner data where relevant, reaction-to-fire evidence and repair method. Approve a full-height/area mock-up including joint, corner, penetration, water exposure and deliberate patch repair.
05 · Quality control
Inspection plan from submittal to handover.
01Grey Microcement Finish: identity and source
- Inspection
- Grey microcement layered mineral/resin system, typically about 2–3 mm only where selected manufacturer confirms; substrate and sealer included.
- Acceptance / hold point
- Documents, labels and physical material all identify the same Grey Microcement Finish construction and source.
02Grey Microcement Finish: control sample
- Inspection
- Continuous hand-trowelled tonal movement across walls, joinery and selected furniture.
- Acceptance / hold point
- One manufacturer/system warranty covers all layers and substrate route.
03Grey Microcement Finish: first-off fabrication
- Inspection
- Repair cracks, honour movement joints, reinforce as required and apply one manufacturer’s full cure/sealer sequence.
- Acceptance / hold point
- Substrate hold point and waterproofing test are complete before finish.
04Grey Microcement Finish: exposure and care trial
- Inspection
- Wet areas depend on underlying waterproofing; hot dry application can shorten working time and alter colour. Use sealer-compatible neutral cleaner and renew topcoat by condition, not a generic calendar.
- Acceptance / hold point
- Repair/stabilise substrate, honour joints and test full system including sealer.
05Grey Microcement Finish: delivery release
- Inspection
- Reject substrate read-through, hairline cracking, dark water patches, trowel burns, pinholes or visible patch repair outside control.
- Acceptance / hold point
- Grey Microcement Finish is released only when no stated rejection condition is present and the signed reference remains traceable.
| Stage | Inspection | Acceptance / hold point |
|---|---|---|
| 01Grey Microcement Finish: identity and source | Grey microcement layered mineral/resin system, typically about 2–3 mm only where selected manufacturer confirms; substrate and sealer included. | Documents, labels and physical material all identify the same Grey Microcement Finish construction and source. |
| 02Grey Microcement Finish: control sample | Continuous hand-trowelled tonal movement across walls, joinery and selected furniture. | One manufacturer/system warranty covers all layers and substrate route. |
| 03Grey Microcement Finish: first-off fabrication | Repair cracks, honour movement joints, reinforce as required and apply one manufacturer’s full cure/sealer sequence. | Substrate hold point and waterproofing test are complete before finish. |
| 04Grey Microcement Finish: exposure and care trial | Wet areas depend on underlying waterproofing; hot dry application can shorten working time and alter colour. Use sealer-compatible neutral cleaner and renew topcoat by condition, not a generic calendar. | Repair/stabilise substrate, honour joints and test full system including sealer. |
| 05Grey Microcement Finish: delivery release | Reject substrate read-through, hairline cracking, dark water patches, trowel burns, pinholes or visible patch repair outside control. | Grey Microcement Finish is released only when no stated rejection condition is present and the signed reference remains traceable. |
Required approval evidence
- +Grey Microcement Finish: Identity/source evidence: Grey microcement layered mineral/resin system, typically about 2–3 mm only where selected manufacturer confirms; substrate and sealer included.
- +Grey Microcement Finish: Signed selection evidence: One manufacturer/system warranty covers all layers and substrate route.
- +Grey Microcement Finish: Second technical gate: Substrate hold point and waterproofing test are complete before finish.
- +Grey Microcement Finish: Factory close-out: Repair cracks, honour movement joints, reinforce as required and apply one manufacturer’s full cure/sealer sequence.
- +Grey Microcement Finish: Exposure and care record: Wet areas depend on underlying waterproofing; hot dry application can shorten working time and alter colour. Use sealer-compatible neutral cleaner and renew topcoat by condition, not a generic calendar.
- +Grey Microcement Finish: Delivery rejection record: Reject substrate read-through, hairline cracking, dark water patches, trowel burns, pinholes or visible patch repair outside control.
Questions to close before approval
- 01Grey Microcement Finish: Has the exact identity been declared and evidenced: Grey microcement layered mineral/resin system, typically about 2–3 mm only where selected manufacturer confirms; substrate and sealer included?
- 02Grey Microcement Finish: Which project requirement makes this differentiator necessary: Continuous hand-trowelled tonal movement across walls, joinery and selected furniture?
- 03Grey Microcement Finish: Has the team excluded the non-equivalent route: Cement paint, polished plaster and another microcement brand are not equivalent layered systems?
- 04Grey Microcement Finish: How will the factory prove this execution control: Repair cracks, honour movement joints, reinforce as required and apply one manufacturer’s full cure/sealer sequence?
- 05Grey Microcement Finish: Can the project control this GCC exposure: Wet areas depend on underlying waterproofing; hot dry application can shorten working time and alter colour?
- 06Grey Microcement Finish: Who owns this operating rule after handover: Use sealer-compatible neutral cleaner and renew topcoat by condition, not a generic calendar?
Exact material application
Grey Microcement Finish on a dedicated furniture product.
This material-specific application image shows Grey Microcement Finish on its own product and is not reused by any other material page. Final colour, pattern and finish remain subject to the approved physical sample.
Project notes
From sample to production.
01
What to specify
Select after confirming substrate, fire requirement, cleaning, acoustics, humidity and joint layout. A full installed mock-up is the most reliable approval reference.
02
Fabrication & detailing
Survey substrates and coordinate setting-out with doors, outlets, lighting and joinery. Complete a mock-up before bulk installation and protect finished work from following trades.
03
Colour & finish approval
Wall finishes are approved as installed mock-ups because lighting, substrate, panel joints and hand application materially change the final appearance.
04
Care & maintenance
Follow the approved maintenance guide for the selected system. Dust or spot-clean gently; repair test areas first so colour, sheen and texture remain consistent.
Specification note
This page is a preliminary specification guide. No value, brand reference or material name constitutes automatic compliance. Current product data, test reports, physical sample or slab and the furniture construction must be approved for each project before ordering or manufacture.
Related materials